Methodology
Every measurement archive on this site references this page. If an archive and this page ever disagree, this page wins — and we will say so in the archive's revision history.
1 · Measurement environment
Speaker measurements use gated sine sweeps in a quiet, lightly damped room sized to suppress reflections within the measurement window. Below the gate limit, low-frequency data is spliced from ground-plane measurements. Electrical measurements (amplifiers, sources) are taken at the bench with resistive loads and a calibrated analyser loop. Temperature and humidity are logged with every session because air absorption above 10 kHz is not a myth.
2 · Equipment
Each archive lists its own equipment, but the shared backbone is:
- A calibrated free-field measurement microphone with a current calibration file.
- An audio interface with loopback reference for amplitude calibration.
- A resistive load bank (non-inductive) for amplifier tests.
- Calibrated microphone stands and laser-verified distances.
When equipment changes, archives taken with the previous setup keep their original equipment list and are re-measured as capacity allows.
3 · Test flow
- Calibration first. Microphone and loopback calibration files are captured the same session as the data.
- Averaged sweeps. Multiple sine sweeps averaged to push noise below the signal of interest.
- Fixed geometry. Distance, height and angle are recorded to the centimetre and reproduced for comparisons.
- Raw files kept. Processed graphs always derive from stored raw captures; nothing is smoothed into existence.
4 · Smoothing
Display smoothing is stated on every chart — typically 1/12 octave for broadband views. Raw unsmoothed data is always available in the downloadable CSVs. Narrow-band anomalies wider than the smoothing window are reported even when display smoothing would hide them.
5 · Evidence levels
Every record carries exactly one of these labels:
- concept — direction and intent; no dataset.
- simulation — modelled behaviour (BEM, FEA, SPICE), not yet built or tested.
- sample — synthetic dataset representing the shape of future measurements. Banner + watermark +
-samplefilenames apply, and the page stays noindex. - measured — captured in our lab with the equipment and flow above; page becomes indexable.
- independently-tested — reproduced by a third party we link to.
A record can only move forward through these levels, never silently backward; a downgrade is a published correction.
6 · Data versioning & revision policy
- Every dataset file is versioned by measurement date in its archive.
- Replacing a dataset never deletes the previous one — the archive gains a revision entry explaining what changed and why.
- Sample datasets are replaced wholesale when measured data arrives; the replacement is flagged in the archive header.
- Corrections of fact are published in the journal, not slipped in quietly.
7 · What we will not do
- No graphs without a stated environment, distance and smoothing.
- No conclusion language stronger than the evidence level allows.
- No synthetic data presented without its three markers.